GENERAL - ALL LADDERS
Fire service ladders in general, are simple tools normally used to gain access to levels above the ground; ie: roof access, 2nd or 3rd
story windows, etc.
These ladders are generally carried on side mounts on pumpers/engines or are mounted internally under the turntable of the aerial device/boom
of the ladder truck. Maintenance of these ladders is a simple task normally required only once every 6 months UNLESS your department has a higher
run frequency than approximately 100 runs a month. In the higher usage bracket, we suggest you increase your maintenance to every 3 months or sooner.
NOTE: Training Schools, etc. - We suggest you do your general maintenance at least monthly.
General maintenance for ladders is a simple process of taking a little time to visually inspect all
the parts, beams, fasteners and rungs for damage or wear and apply wax to all contacting surfaces.
LADDER LOGS
At the time of inspection, we suggest you start/create a maintenance log for each ladder. This log can then be used to supplement your annual
testing log for each ladder and will provide a useful history to be able to track any and all ladder damages or repairs that may happen.
SAMPLE LADDER LOG:
As brief or as detailed as you prefer. One for each ladder, on each
Engine or Truck.
Date: _______________________
Ladder Type:
_______ Ext. _______ Roof _______Other
Length: ________________________
Parts:
| Feet: |
_____ OK |
_____ Not OK |
| Locks: |
_____ OK |
_____ Not OK |
| Rope/Cable: |
_____ OK |
_____ Not OK |
| Beams: |
_____ OK |
_____ Not OK |
| Rungs: |
_____ OK |
_____ Not OK |
Noted Problems: (When and where for future reference)
________________________________________________________________
Visual (small dents:
________________________________________________________________
Corrections required:
________________________________________________________________
Date fixed, etc.:
________________________________________________________________
Ladder sections cleaned and rewaxed and returned to service:
________________________________________________________________
Date and Signature:
________________________________________________________________
NOTE: Create your own log form or use ours, it doesn't matter, but please do it.
The idea of regular maintenance and a written log is to be able to track any problems before they can become accidents waiting to happen.
LADDER TESTING
Ground ladder testing can become an expensive lesson for the unprepared Fire Department. We suggest
all departments considering/or preparing to test their ground ladders do their homework before
testing any ladders. With the NFPA 1932 standard -1984 edition changes, requirements for all fire
department ground ladders have changed considerably. It became very obvious that some of the
ladders manufactured before 1984 may not be able to pass the new required test. The homework we
suggest would be to get a copy of the ladder manufacturers current ladder catalog and check the
listed sizes against the sizes you have in service.
If the nested height of your ladder is less than the current nested height in the catalog or on
website for the same length and style of ladder, you can assume yours will NOT pass the tests.
We also suggest you check the catalog or website for ladder rail sizes. If the catalog/website
sizes are larger than your rail sizes for the same type and length of ladder you probably will
NOT pass the tests.
Remember if your ladders are OK, service testing, as required by NFPA 1932 are not destructive.
The only ladders that will not be able to pass the NFPA 1932 tests are ladders you should not be
using in the first place. Fire service ladders are assumed to be able to safely support a 750 lb.
working load with a 4:1 safety factor. Industrial ladder equipment uses a maximum load of 300 lbs.
with a 4:1 safety factor. Surely, fire service ladders can handle at least twice that load.
ARE YOU SURE?
The only way you and your department can be absolutely sure your ladders are safe to use at 750 lbs.
is to test.
Why 750 lbs.? What does this mean?
Any ladder with a 750 lb. in service duty rating and a 4:1 safety factor as required by NFPA 1932
can be used as follows:
Three people at one time:
- Three firefighters with full turnout gear and air packs.
- Two firefighters and an unconscious victim.
- Two firefighters and a charged hose.
4:1 Safety Factor? What does this mean?
The 4:1 safety factor used in the design and manufacture of ladders today means that the ladder,
once in perfect erected position, is really able to support 4 times the 750 lb. specified load.
(That is 3,000 lbs.)
Why such a high load rating? Seems 3,000 lbs. is a bit higher than needed.
Not true. The load is a static load only - nothing moving, no shock loads, no dynamic loads.
Once a smaller load starts to move on a ladder, the dynamic load increases rapidly. Did you know
it is possible for one man to put over a 2,000 lb. load on a ladder by himself? All you have to
do is decrease the climbing angle to say, only 45 degrees instead of 75.5 degrees and have the man violently
bounce up and down on the ladder. Therefore, when two or three firefighters are moving and working
from the ladder, the dynamic loads are way over their simple combined weight. It becomes very
obvious that fire service ladders must have at least a 4:1 safety factor to be able to withstand
their design loads.
Why does the NFPA 1932 standard require a 500 lb. horizontal bend test instead of a
750 lb. test?
NFPA 1932 standard recognizes the 750 lb. test requirement in the Design Verification part of its
standard in NFPA 1931. This standard is a Design Verification standard to be used by Ladder
Manufacturers only. The service testing standard - NFPA 1932 uses the 500 lb. test with a pass - no pass permanent set requirement instead of a 750 lb. test which only has to be able to
be passed - set in the ladder is allowed, and after the 750 lb. test is passed, the ladder is
destroyed.
Therefore, the 500 lb. service test is a ladder test and is not destructive. If your ladder can
pass the 500 lb. test, you are assured of at least a 500 lb. capacity with a 4:1 safety factor
and probably more, and of course, the test has not destroyed the ladder.
BASIC TESTING PROCEDURE
Horizontal Bend Test/Visual Inspection
Place the ladder to be tested upon a pair of sawhorses. The horses are placed 6" in from each end
of the ladder - top and bottom. Be sure the ladder is fully extended and as level as possible.
We suggest you now do your visual inspection of the ladder before the load is placed. Check for
any problems noticeable - loose nuts/bolts, bent rungs/loose rungs, any problems/areas that no
longer look factory fresh. If everything looks OK - proceed to the load test.

- The test load required is 350 lbs for pre-load and 500 lbs for final load.
- The pre-load of 350 lbs is applied to the center area of the ladder covering 32" in length and at least the width of the ladder section. (Center of the ladder and no more than 16" on each side of the center.)
- Wait one minute and remove the 350 lb pre-load and measure from the center of the ladder to the ground - record the measurement.
- Apply the full 500 lb test load to the load area, wait 5 minutes and again remove the 500 lbs.
- After another 5 minutes, measure from the center of the ladder to the ground - record the measurement.
If the difference between measurements is greater than 1/2" for ladders up to 25 ft or 1" for
ladders 26 ft to 34 ft or 1-1/2" for ladders over 35 ft - the ladder has failed. Remove from
service and destroy. If the amount of set is less than allowed, you have passed the test.
GENERAL MAINTENANCE
Tested, clean and maintained ladders last longer and properly lubricated ladder sections slide
easier and simply work better. (No DUO-SAFETY ladder requires more than 75 lb. pull to raise
any sections). If you have any ladder in service that seems to require more than a 75 lb. pull
to raise, we suggest immediate cleaning and waxing of all contact surfaces and lock parts.
Regardless of the manufacturer, age or material, all ladders will extend and retract easier and
smoother if the contacting parts have some lubrication on these surfaces. Did you ever notice
that a ball bearing rolls much easier and lasts a lot longer if you supply a bit of oil or grease??
Whenever surfaces rub together, you must lubricate or friction increases.
DUO-SAFETY LADDER suggests plain old candle wax or paraffin wax as your best lubrication.
This wax coats and works into the pores of the ladder material and does not easily wash away with
frequent water baths. This candle wax is also not costly and is readily available anywhere.
We suggest you extend the ladder, and simply rub the candle wax over and onto all of the contacting
parts.
CLEAN and WAX and INSPECT every 6 months or sooner based on your run frequency to keep your ladders
accident free. Be sure your ladders are ready for each use and they will always be ready to carry
you to greater heights.
NOTE: Do not forget to coat the lock parts (lock hook and finger) with wax as this reduces the
wear on the rungs and these parts move over the rungs every time the ladder is used (see the
section on ladder locks/pawls for further details).
ALUMINUM LADDERS:
Solid Beam or Truss Beam
MATERIAL - 6061-T6 alloy - minimum yield 38,000 p.s.i. - CAUTION: aluminum conducts electricity.
CLEANING: Mild soap (ex: Ivory dish soap) and water works well - be sure to flush inside
the rails and rungs to clear them of road salts, etc. We suggest a plastic scrub pad to buff the
surface to a smooth finish. Be sure to clean and rewax the slide areas at the same time.
Be sure to check any heat sensor labels as you clean and wash and try not to wash away the labels.
(Replacement labels are readily available from the ladder manufacturer). NOTE: Use of harsh soaps
or chemicals can sometimes turn heat sensor labels dark, that is why we recommend using a mild soap
for cleaning.
RAILS AND RUNGS: Aluminum is a malleable metal and is subject to dents and nicks, etc.
NOTE: Small dents and/or nicks on the beams and rungs are not uncommon and are not grounds to
fail a ladder. If you have any concern about any dents, etc., we suggest a load test to be
sure the dents are not serious. Be sure to record the location and size for future reference.
REPEAT: Be sure the rungs are all tight as the rung to rail joint is the only thing that holds
the two beams together. If any rung is loose - remove the ladder from service, repair and service
test before further use and putting ladders back into service.
ALUMINUM RUNG REPLACEMENT
All rungs are 1-1/4" diameter by .065" wall thickness. (Standard Rung), unless your section width
is wider than 24". In this case, you probably have heavy rungs - 1-1/4" diameter by .105 wall
thickness.
Note: All replacement rungs are supplied 24" - standard .065 wall.
To remove any welded rung from the rail or plate, you must use a rung reamer tool.
The reamer tool pilots itself in the rung hole, and cuts only the old rung away, thereby leaving
the proper size hole for the new rung to be welded in place. If our standard reamer tool will not
fit inside your rung - be sure the ladder is a Duo-Safety Ladder and check the width of the section.
If the section width is over 24" wide - you have heavy rungs in that section. Heavy rungs are
supplied to meet the NFPA 1932 load rating in all sections wider than 24" wide. In these cases you
must order our Heavy Rung Reamer Tool and heavy rungs for replacements.
Duo-Safety Ladder Corp. ladders all depend 95% on the welded rung joints to hold all ladders
together. The minimum yield of our welded joint is 8,000 P.S.I.
The expansion process on the inner plates is a 5% back up system to help protect the weld joint
from flexing and cracking.
Thus - if you only replace a few rungs per section - you do not need the expander tool. But if you
replace more than 3 rungs per section, we suggest you use the expander tool.
FIBERGLASS LADDERS:
MATERIAL: Vinyl ester, high temperature resin system with ultraviolet inhibitors, flame retardant
additives and continuous strand rovings pultruded to create a non-conductive ladder rail system.
CLEANING: Mild soap and water works well - be sure to flush inside the rails to clear same of road salt,
etc. We suggest any car wax available as a suitable surface restorer. Use approximately the same care
and clean up required as any automotive finish would require. Be sure to check all rungs and other parts
for tightness when cleaning and be sure to rewax so the sections will slide easily.
Fiberglass ladders are not malleable and do not dent; however, nicks and scratches and scrapes can be
very common. If you have any doubts, we suggest a load test to be sure the nicks and scratches are not serious.
Repairs of small surface nicks and scratches generally require only slight sanding of same and an application
of clear epoxy glue to the nick or scratch. Be sure to sand smooth after the glue dries. NOTE: This
type of repair is only to be used for small surface scratches, etc. and only after a load test has been passed.
WOOD LADDERS:
Solid Beam Models
MATERIAL: Wood - generally West Coast Douglas Fir with hickory rungs; however, some models may have
aluminum rungs. Wood is a non-conductive material when dry and clean.
CLEANING: Mild soap and water works well to clean all surfaces. Do not soak wood ladder rails or rungs with
excessive water or water pressure as this tends to swell the wood and/or peel the finish from the wood. Wood
ladders are normally coated with a clear varnish finish to protect the wood from the elements and to help it remain
non-conductive. After cleaning, be sure to rewax all contact surfaces so they will slide easily. If the varnish
finish has become scratched, nicked, dented or damaged, we suggest immediate spot repair of the bare wood to preserve
the wood and keep the ladder non-conductive.
FACT: Wood rails and wood rungs expand and contract with changes of both humidity and temperatures. Because
of this problem, it is very important that rung tightness is checked regularly and any and all rung tie rods be checked to
be sure they are tight.
REMEMBER: Only the rung to rail joint holds the side beams together. In cold
regions of the country, the heating of the fire station causes the rungs to become loose as the wood shrinks
from the loss of moisture.
Wood Beam Truss Models:
These wood models are constructed with top and bottom wood pieces and truss blocks/rung blocks between the top and
bottom wood truss rails.
WARNING: The wood joints/glue joints between the blocks and strips are very likely to fail if the bolts and
nuts are not kept tight. You must be sure these bolts are tight before any load testing is ever done. If you
test without tight bolts, you will fail your glue joints and fail your ladder. These glue joints must have the
tight bolt assemblies as a back up to support the glue joints during any load testing that approaches the maximum
capacity of the ladder - 500 lb. horizontal load test/annual load test.
REMEMBER: It is 4 times harder to carry the load horizontally/flat than it is at 75 degrees or in erected
position.
The visual inspection part of your maintenance program becomes very important on any wood ladder as
most noticeable damaged areas require immediate attention and repair just to maintain the varnish
finish and keep the wood from deteriorating.
Only a load test can tell you if any ladder can still carry the load it was designed to carry, and
only a 500 lb. center load test can tell you if you really have a fire service ladder with a 4:1
safety factor. (Please refer to the ladder testing section and NFPA 1932-current edition for
further information on horizontal bend test instructions)
SPECIAL TYPES OF LADDERS
ROOF LADDERS: Maintenance on roof ladders is the same as already covered under the previous sections.
Please refer to the proper section that covered the type of material you have in service.
ROOF HOOKS: Fire service roof ladders are supplied with spring loaded, directionally swiveling and locking
hook assemblies capable of 1,000 lb. load per hook/2,000 lb. load per pair. These roof hooks normally only require
occasional cleaning to maintain proper operation - mild soap and water works well. If the points are dull - file sharp
and cover with a bit of paint. If the springs become weak - please call the factory for replacements and instructions.
FOLDING LADDERS: Maintenance is again the same as the general maintenance covered earlier - refer to the
proper section covering the type of material you have in service. Mild soap and water works well for cleaning purposes.
We suggest you check the rung assembly rivets regularly to be sure they are not worn excessively.
When these rung mounting rivets become sloppy and loose, we suggest you replace the ladder as these rivets are
brass and are meant to provide a hinge/bearing assembly for this folding ladder. These are not
field replaceable without special tools, and these tools are not available because of cost.
Be sure the lock assembly is also tight and properly locks the ladder in the open position. These lock assemblies
can be tightened - carefully - with a hammer and punch. Please call us if you are not sure.
WARNING: This ladder folds side to side (together) watch carefully where you place your
hands/fingers when closing and opening ladder. (please refer to the IFSTA-Fire Service Ground
Ladder manual for proper use and training information.) If the lock assembly rung is bent or
does not properly lock DO NOT USE LADDER as it may not be safe to climb.
A-FRAME/COMBINATION LADDERS: Please refer to the earlier covered sections for general maintenance in
reference to materials of the ladders you have in service.
HINGES/LOCK ASSEMBLIES: Be sure to inspect the hinge hardware and fasteners and replace anything that
appears to be worn, damaged or rusty. A few drops of any type of oil works well on the hinges and of course, soap
and water works well on all the other parts. Be sure to check the spreader arms, bars and parts to be sure
everything still works and fits together properly. These parts are vital in the A-frame position and must be able
to properly engage before the ladder would be safe to use in the A-frame position.
35-B JACKKNIFE LOCKS: These locks must be engaged before using the ladder as a single
ladder. Also, please note that the hinge on this model must be under the ladder/bottom side as
you climb to be in the proper use position. This allows the butt ends of the rails to pinch
together under load rather than allowing all the load to be on the locks. WARNING: Use with
the hinge on top of rails is not safe. (Please refer to the IFSTA Fire Service Ground Ladder
manual from proper training and use of ladders)
POMPIER LADDERS: Pompier hook maintenance basically consists of cleaning, sharpening with a file and
painting to stop any rusting that occurs over time.
Rung to shaft hardware - inspect and tighten or replace if anything becomes loose. Be sure to check the solid steel rivets that hold the hook to the shaft. If any looseness starts at this point,
tighten the fasteners at once. If this is no longer possible - shaft enlarged - we suggest you drill out the
rivets and cut the shaft back approximately 6" and redrill and refasten with at least 5/16" steel bolts
and lock nuts. Call the factory for further information.
LADDER PARTS/ACCESSORIES:
LADDER LOCKS/PAWLS: Spring operated, automatic lock assemblies that engage and lock upper sections to lower
sections, always operating in pairs.

Duo-Safety Spring Lock Assembly
- Lock housing & cover plate (not shown)
- Lock hook
- Finger (note position)
- Spring
- Mounting bolt holes
- Shoulder bolt hole
These lock assemblies always have a rung mounted between them. This rung that is used between the locks is the
only rung (except for some roof hook models) that is not fastened to the side rails. Because these rungs are not
mounted to the side rails, we are forced to use a special rung mount bracket. The rung is fastened to this
by 4 each rivets, which must be removed and replaced if you remove the locks. We suggest you request our lock
housing repair kit before you remove the locks. This kit has all the replacement fasteners and new springs that
are normally required, plus instructions. Please follow the instructions closely so proper lock function can occur.
NOTE: Lock assemblies are to be tight, but you can crush the housing and pinch the lock parts if you overtighten the
mounting bolts. Be sure to flush the housings with soap and water and apply some oil to the pivot points before you return the ladder
to service.
NOTE: If the rung mount bracket (called a Lock Rung Holder) and used on older model ladder
locks) cracks or becomes broken, please remove and replace with the new factory replacements
available. You only have to remove these brackets to replace - do not remove the lock housings
to replace only the rung brackets. Please call if you have any questions.
PRONG FEET/SPIKES/BUTT SPURS and END CAPS: These parts are either aluminum or steel (on older
models) and are fastened to the side rails with rivets and/or bolts. Be sure to check these parts
for shape and tightness and replace or tighten as needed when you are checking the rest of the
ladder assembly. Bolts and rivets have been known to be sheared off and/or loosen after walking a
ladder or using it to break windows and doors. Please check these parts. NOTE: Most
replacement End Caps and Prong Feet are now all Aluminum extruded parts for replacement.
SAFETY SHOES: A rubber padded optional swivel foot or shoe mounted to the bottom of the section. These rubber safety shoes are offered as
a ladder option to the standard prong foot/spike. The rubber safety shoe is meant to be used on hard, smooth surfaces where spikes may slip
because they cannot dig in. These safety shoes also may rust, and because of this, they require cleaning and checking at least yearly. NOTE:
Replacement rubber pads are available from the factory.
PULLEYS and HALYARDS: All larger extension ladders are supplied with halyards (rope) and pulleys so the upper sections can be easily
extended.
PULLEYS: The present pulleys are all aluminum with brass oil-lite bushings supplied either as single or double sheave. These pulleys are
available as replacements for all of our older models. Please call for exact application details as we use several configurations with and without
rope mounting features. Cleaning and oiling of pulleys is a good idea - recommended once a year.
HALYARDS/ROPE: All rope furnished with all Duo-Safety Ladders as standard still continues to be pure 3/8" manila rope. The factory uses
manila rope because it offers the least expensive and best combination of desirable features available in rope today:
- Soft - not stiff
- Abrasive - does not slip in gloves
- Will not stretch with heat exposure
- Has a minimum yield of at least 825 lbs. (No ladder requires more than 75 lbs. to raise)
- Readily available for replacement in any local hardware store - when it wears out
However, halyard replacement can be any rope material you choose - as long as it meets the minimum
yield requirements per NFPA.
SPECIAL NOTE: The factory is not able to provide larger diameter pulleys because the space
between sections is so small. Our standard pulleys accommodate 3/8" - 1/2" diameter ropes and
may cause rope to wear rapidly. If in doubt of any rope quality, always replace the rope with new!
ROPE END FASTENERS: Always be sure the rope thimble is in place at the end where the rope
attaches to the rung so the rope will not be cut by any sharp corners. The factory has always
opened the twisted rope and passed the rope back through itself at least twice to secure it.
This method of fastening is as strong as the rope itself. Duo-Safety does not object if any fire
department wishes to add any extra safety features or accessories to any ladder that the department
may deem to make the ladder safer and/or easier to use. As long as these modifications do not
interfere with the ladder normal performance and use. If you are in doubt about any feature you
wish to add, contact the factory for our recommendations before you install any new items.
SAFETY NOTE: Safety is a shared responsibility between the product manufacturer and the
user. The factory can not make any ladder accident free if proper use and training is not followed
first!
FIRE LADDER LABELS:
One set/pair of Danger/Electrical/Angle labels are required for each ladder. The labels should be placed at the
bottom of the ladder, outside the rail of the base section, both sides, between the 4th and 5th rung up from the bottom. Be sure the left label is
placed on the left side, and the right label is placed on the right side. If placed on the wrong sides of the ladder, they will not make sense for
ladder placement.
HEAT SENSOR LABELS: These are visual warning labels furnished on all aluminum and fiberglass ladders since January, 1984.
These labels are heat sensitive material that turn black if any heat is ever present that is greater than approximately 300 degrees F. The 300 degree F
temperature is used because once aluminum fire ladder materials (6061-T6 alloy) reach this 300 degree F (even if only for a moment), the ladder
material may have lost at least 25% of its load capacity. This heat exposure effect is not reversible in the ladder and can continue to accumulate
over its entire life.
WARNING: All ground ladders Aluminum and Fiberglass should never be placed near apparatus
exhaust systems. Placing any ladder near an extreme heat source can turn heat labels black without
the ladder even being used in a fire scene. Many different heat sources from any part of an
apparatus can expose a ladder and weaken its strength. Use caution when removing a ladder from
apparatus for proper placement on ground and at a fire scene.
NOTE: If any heat sensor label becomes black - remove the ladder from service at once and
have the ladder load tested before the ladder is ever used again. If the ladder passes the load
test, replace the heat sensors and return the ladder to service. Replacement heat sensor labels
should only be placed on ladders that have passed the load test. If the ladder does not pass the
test, remove from service and destroy immediately. Call the factory for details on replacement
labels available.
REMEMBER: Heat sensor labels that look OK do not make the ladder safe to use. ONLY a
ladder test can determine if any ladder is safe for use.
NOTE: As of 1994, NFPA 1932 now requires 4 heat sensors per ladder section. Each heat sensor
has an expiration date printed on it. Any expired labels must be replaced ONLY after a horizontal
bend test has been performed on the ladder. Place 2 heat sensor labels below the 2nd rung from the
top of each section inside the beam. (1 inside the right beam - 1 inside the left beam) Place the
other 2 heat sensor labels (one with instruction label) below the approximate middle of the section
inside the beam. (1 inside the right beam - 1 inside the left beam)
CONCLUSION:
Only by passing the load test can you be sure the ladder is indeed a 750 lb. or 300 lb. duty rated
fire service ladder with a 4:1 safety factor and still safe to use. Duo-Safety Ladder Corporation
suggests and recommends that all fire departments obtain and fully read and understand all the
requirements of the current applicable standards and training instructions as released by the
National Fire Protection Association (NFPA) 1932-current edition, and the International Fire
Service Training Association (IFSTA) Fire Service Ground Ladders.